How battery runtime is calculated
A battery stores energy, and the load uses it up at a rate. The capacity on most batteries is in amp-hours (Ah), which becomes energy in watt-hours (Wh) once you multiply by the voltage. Divide that energy by the power of the load in watts and you get the hours.
Watt-hours = amp-hours × volts
Usable watt-hours = watt-hours × usable share × efficiency
Runtime (hours) = usable watt-hours ÷ load in watts
Current = load in watts ÷ battery volts
Two percentages adjust the result. The usable share is how much of the rated capacity you plan to draw: battery makers publish a recommended depth of discharge for each chemistry and model. The efficiency covers what an inverter or converter loses when it turns battery power into what your device uses. Both start at 100% in the calculator; enter the figures from your own data sheets.
Worked example: 100 Ah at 12 V running 100 W
A 100 Ah battery at 12 V holds 100 × 12 = 1,200 Wh. A 100 W load draws 8.33 A from it.
- At full rated capacity and no losses: 1,200 ÷ 100 = 12 hours
- Using half the capacity through an inverter that is 90% efficient: 1,200 × 0.5 × 0.9 = 540 Wh, or 5.4 hours
The same battery, the same load, and the answer more than halves. That is why the usable share and the efficiency matter as much as the capacity on the label.
Runtime at different loads
The table shows a 12 V, 100 Ah battery under loads from a small light to a microwave-size appliance. The last column applies 80% usable capacity and 90% efficiency as an example.
| Load | Current | Runtime | With 80% usable and 90% efficiency |
|---|---|---|---|
| 25 W | 2.08 A | 48 h | 34.56 h |
| 50 W | 4.17 A | 24 h | 17.28 h |
| 100 W | 8.33 A | 12 h | 8.64 h |
| 200 W | 16.67 A | 6 h | 4.32 h |
| 500 W | 41.67 A | 2.4 h | 1.73 h |
| 1000 W | 83.33 A | 1.2 h | 0.86 h |
Real batteries deliver less than their rating when the current is high or the battery is cold, so the runtime at heavy loads tends to fall short of the simple figure. Battery data sheets often give capacity at a stated discharge rate; check yours if you plan to draw a lot of current.
Sizing a battery for the hours you need
Switch the calculator to the battery I need and enter the hours instead of the capacity. It works the formula backwards: energy used = watts × hours, divided by the usable share and the efficiency, then divided by the voltage for amp-hours.
For a 60 W load that must run 10 hours on a 12 V battery, with 80% usable capacity and a 90% efficient inverter, the energy used is 600 Wh and the battery must hold 833 Wh, or 69.4 Ah at 12 V. Round up to the next battery size you can buy.
For a UPS, a camper, a boat or a backup system, add up the watts of everything that runs at the same time. The watts to amps calculator converts device ratings, and the electricity cost calculator shows what the same energy costs from the grid.
Amp-hours, watt-hours and series or parallel banks
Amp-hours only compare batteries of the same voltage. A 100 Ah battery at 24 V stores twice the energy of a 100 Ah battery at 12 V, so watt-hours are the fairer measure. Many portable power stations print their capacity in watt-hours directly: pick Wh as the unit and type it in.
For a bank of identical batteries, two in series double the voltage with the same amp-hours, and two in parallel double the amp-hours at the same voltage. Either way the watt-hours double. Enter the voltage and capacity of the whole bank. For solar charging, the solar panel calculator estimates how much a panel array produces, and the generator size calculator covers a fuel backup.
Battery Runtime Calculator FAQ
How long will a 100Ah battery last?
At 12 V it holds 1,200 Wh. A 100 W load runs about 12 hours at full rated capacity, or 5.4 hours using half the capacity through a 90% efficient inverter.
How do I convert amp-hours to watt-hours?
Multiply the amp-hours by the battery voltage. 100 Ah at 12 V is 1,200 Wh; 50 Ah at 24 V is also 1,200 Wh.
What battery size do I need to run 60 watts for 10 hours?
The load uses 600 Wh. With 80% usable capacity and 90% inverter efficiency, the battery must hold about 833 Wh, or 69.4 Ah at 12 V.
Why does my battery run out sooner than calculated?
High currents, cold temperatures, an aging battery and inverter losses all reduce the energy you get. Use the usable share and efficiency from your data sheets for a closer estimate.
How many amps does a 100 watt load draw from a 12 volt battery?
Amps = watts ÷ volts, so 100 ÷ 12 = 8.33 A, before any inverter losses.