Dryer Vent Length Calculator

A clothes dryer duct can run 35 feet from the wall to the outlet outside, minus 2.5 feet for every 45-degree bend and 5 feet for every 90-degree bend, under the International Residential Code (IRC) Section M1502. A run of 20 feet of straight duct with two 90-degree elbows counts as 30 feet, so it is 5 feet under the limit. Enter your straight length and your bends to check your own run.

Enter your duct run

All the straight pieces from the wall behind the dryer to the outlet outside, in feet. 20 is only an example.

Each one counts as 2.5 ft. Enter 0 for none.

Each one counts as 5 ft. Enter 0 for none.

Planning check only: your dryer's installation instructions and your local building department have the final word.

Equivalent duct length

30 ft

5 ft under the 35 ft limit

Your duct run
Straight duct20 ft
45-degree bends0 × 2.5 ft = 0 ft
90-degree bends2 × 5 ft = 10 ft
Equivalent length30 ft
Code limit (IRC M1502)35 ft
Length left5 ft
Longest straight duct with these bends25 ft
Longest straight duct with 0 bends of 45 degrees and 0 to 4 elbows of 90 degrees
90-degree elbowsBends count asLongest straight duct
00 ft35 ft
15 ft30 ft
210 ft25 ft
315 ft20 ft
420 ft15 ft

Equivalent length = straight duct + 2.5 ft for each 45-degree bend + 5 ft for each 90-degree bend, measured from the wall to the outlet outside. The limit is 35 ft for a rigid metal duct 4 in. across, as the DOE Building America Solution Center summarizes IRC Section M1502. The flexible transition duct between the dryer and the wall is not part of that run and should be no longer than 8 ft.

Planning check only: your dryer's installation instructions and your local building department have the final word.

How long can a dryer vent be?

The DOE Building America Solution Center, run by Pacific Northwest National Laboratory, summarizes IRC Section M1502 this way: the duct length from the wall to the outlet terminal should be no more than 35 feet, and that length should be decreased by 2.5 feet for every 45-degree bend and 5 feet for every 90-degree bend the duct makes. The same guide says the exhaust duct should be rigid metal 4 inches in diameter.

So 35 feet is the limit for a perfectly straight run. Each elbow uses up part of it, so a run with many turns must be shorter.

How is the equivalent length worked out?

The dryer vent length calculator adds the bends to the straight pieces and compares the total with 35 feet.

Equivalent length (ft) = straight duct (ft) + 2.5 × bends of 45° + 5 × bends of 90°
Length left (ft) = 35 − equivalent length
Longest straight duct (ft) = 35 − 2.5 × bends of 45° − 5 × bends of 90°

With 12 feet of straight duct, two 45-degree bends and one 90-degree elbow, the bends count as 10 feet, the run counts as 22 feet and 13 feet are left. A basement run of 25 feet with three elbows counts as 40 feet, 5 feet too long. Seven elbows alone use 35 feet, the whole allowance.

Example dryer duct runs against the 35 ft limit
Run (example)Straight ductEquivalent lengthResult
Straight out the wall, no elbow6 ft6 ft29 ft to spare
Two 90-degree elbows to reach an outside wall20 ft30 ft5 ft to spare
One 90 and two 45-degree bends12 ft22 ft13 ft to spare
Up through the attic: four 90-degree elbows16 ft36 ft1 ft too long
A long basement run with three elbows25 ft40 ft5 ft too long

How many elbows can a dryer vent have?

The code does not count elbows; it counts feet. Each 90-degree elbow takes 5 feet, so the number of elbows you can use depends on how much straight duct you need. The table gives the longest straight duct left for 0 to 4 elbows.

Longest straight duct for a number of 90-degree elbows (no 45-degree bends)
90-degree elbowsElbows count asLongest straight duct
00 ft35 ft
15 ft30 ft
210 ft25 ft
315 ft20 ft
420 ft15 ft

Two 45-degree bends take the same 5 feet as one 90-degree elbow, so a gentle offset made of two 45s costs no more than a single sharp turn.

What counts in the length, and what does not?

  • Counted: the duct from the wall behind the dryer to the outlet terminal outside, with every bend in it.
  • Not counted: the transition duct, the short connector between the dryer and the wall. The Building America guide says it should be listed to UL 2158A and no longer than 8 feet.
  • Your dryer's own limit: the same guide says you may instead "follow the duct length recommendations specified by the manufacturer (2009-2018 IRC M1502, see Compliance tab)". Read the installation instructions of your dryer before you buy duct.

If your run is too long, move the dryer, reroute the duct with fewer elbows, or check whether the manufacturer allows more. Measure the run with a tape before you buy: the linear feet calculator adds up several pieces, and the CFM calculator sizes the other exhaust fans of the house.

Sources

  • U.S. Department of Energy, Building America Solution Center (Pacific Northwest National Laboratory), "Proper Clothes Dryer Venting", last updated October 7, 2022: 35 feet from the wall to the outlet terminal, 2.5 feet per 45-degree bend, 5 feet per 90-degree bend, rigid metal duct 4 inches in diameter, transition duct listed to UL 2158A and no longer than 8 feet, the manufacturer's length as an alternative (IRC Section M1502).

Planning check only: your dryer's installation instructions and your local building department have the final word.

Dryer Vent Length Calculator FAQ

What is the maximum length of a dryer vent?

35 feet from the wall to the outlet outside for a straight 4 inch rigid metal duct, under IRC Section M1502 as the DOE Building America Solution Center gives it. Bends shorten that limit, and the dryer maker's instructions may set another length.

How many feet does a 90 degree elbow add to a dryer vent?

Each 90-degree elbow counts as 5 feet, so it lowers the 35 foot limit by 5 feet. A run of 20 feet with two elbows counts as 30 feet.

How much does a 45 degree bend take off a dryer vent run?

2.5 feet for each 45-degree bend, half of a 90-degree elbow. Two 45-degree bends take the same 5 feet as one 90-degree elbow.

Does the flexible hose behind the dryer count in the vent length?

No. The 35 foot length is measured from the wall to the outlet terminal. The transition duct between the dryer and the wall should be listed to UL 2158A and no longer than 8 feet, the Building America guide says.

What if my dryer vent is longer than 35 feet?

Check the installation instructions of your dryer: the code lets the manufacturer's length apply instead. Otherwise remove elbows, shorten the run or move the dryer, and ask your building department before you change the duct.

Last updated . Free to use, no sign-up. How we check our numbers.