How to work out how much insulation to buy
Insulation is sold in bags, rolls or batt bundles, and each package states how much area it covers. The count is the area you want to cover, plus a waste allowance, divided by that coverage and rounded up. The coverage figure is not a constant: a bag of blown-in insulation covers less area the thicker you blow it, so it changes with the R-value you aim for.
Area = length × width (or the area you enter)
Packages = area × (1 + waste %) ÷ coverage per package, rounded up
Depth (in) = target R-value ÷ R-value per inch
For the depth, the US Department of Energy (DOE) gives rules for estimating R-value from depth. In its insulation guide for contractors, loose fiberglass is rated at depth × 2.5, batts of fiberglass at depth × 3.2 and cellulose at depth × 3.7. The calculator divides the other way around to turn your target R-value into inches. ENERGY STAR gives a range of 3 to 3.5 per inch for most common insulation, which it lists as fiberglass, cellulose and mineral wool. ENERGY STAR's range of 3 to 3.5 per inch is a general figure; the calculator uses the DOE values for each type.
Worked example: a 30 ft by 20 ft attic at R-49
The attic floor measures 30 × 20 = 600 square feet. You plan to blow in fiberglass to R-49 and the bag says it covers 35 square feet at that depth, which is the maximum coverage for R-49 on one Johns Manville Attic Protector chart. This first pass adds no waste allowance.
- Bags: 600 ÷ 35 = 17.14, which rounds up to 18 bags
- Area those bags cover: 18 × 35 = 630 square feet, leaving 30 spare
- Depth: 49 ÷ 2.5 = 19.6 inches
Add 5 percent for waste around obstacles and the area becomes 630 square feet and the count stays at 18 bags, with no spare area left in the last bag. In cellulose at R-49, the depth falls to 13.2 inches, and in fiberglass batts it is 15.3 inches.
Recommended attic R-values from ENERGY STAR
ENERGY STAR publishes recommended insulation levels for retrofitting an existing home, based on the 2021 International Energy Conservation Code (IECC) and the climate zone. Its attic columns are headed "Add Insulation to Attic", so they give the R-value to add, not a total level: R-30 in zone 1, R-49 in zones 2 and 3 and R-60 from zone 4 up for an uninsulated attic, and R-25, R-38 and R-49 in the same zones for an attic that already has 3 to 4 inches. ENERGY STAR also says that the recommended level for most attics is R-38, or about 10 to 14 inches depending on the type of insulation.
Find your climate zone on the ENERGY STAR map, and enter the number as the target R-value. Your local building code may set its own figure.
| Type | R-value per inch | Depth for R‑49 |
|---|---|---|
| Fiberglass batts or rolls | 3.2 | 15.3 in |
| Blown-in fiberglass | 2.5 | 19.6 in |
| Blown-in cellulose | 3.7 | 13.2 in |
Bags needed at each R-value
Bag coverage drops quickly as the R-value goes up. The table uses the maximum net coverage from one Johns Manville Attic Protector chart for blow-in fiberglass: 103 square feet per bag at R-19, 62 at R-30, 47 at R-38, 35 at R-49 and 28 at R-60.
| Target R‑value | Maximum coverage per bag | Bags for 600 sq ft |
|---|---|---|
| R-19 | 103 sq ft | 6 bags |
| R-30 | 62 sq ft | 10 bags |
| R-38 | 47 sq ft | 13 bags |
| R-49 | 35 sq ft | 18 bags |
| R-60 | 28 sq ft | 22 bags |
One Johns Manville Attic Protector chart (a 2013 fact sheet) lists 20.3 inches minimum thickness and 35 square feet per bag for R-49. Newer charts differ, so read the chart on your bag. Enter its coverage in the calculator. For a 1,200-square-foot space at R-38 with 47 square feet per bag, the answer is 26 bags.
What is not covered
The calculator counts the horizontal area only. It does not handle wall cavities that differ in depth, vents, baffles, recessed lights, ducts, or air sealing. The BTU calculator sizes a room air conditioner, and the electricity cost calculator turns a device's watts into dollars.
Insulation Calculator FAQ
How many bags of blown-in insulation do I need?
Divide the area by the coverage per bag at your R-value and round up. A 600-square-foot attic at R-49, with 35 square feet per bag, needs 18 bags.
How many inches of insulation is R-49?
About 19.6 inches of loose fiberglass, 13.2 inches of cellulose or 15.3 inches of fiberglass batts, using the DOE values of 2.5, 3.7 and 3.2 R per inch.
What R-value do I need in my attic?
It depends on your climate zone. ENERGY STAR says to add R-30 to R-60 to an uninsulated attic, from R-30 in zone 1 to R-60 in the colder zones, and to add R-25 to R-49 if you already have 3 to 4 inches. Check the ENERGY STAR map and your local code.
Should I add a waste allowance?
It is optional and starts at zero. Add a few percent if the space has many obstacles. Rounding up to whole bags already adds a little.
Where do I find the coverage per package?
It is printed on the bag or the bundle, often in a chart that lists the coverage for each R-value. Bag charts for blown-in insulation give a maximum coverage and a minimum thickness, and both matter.
Can I use this for wall insulation?
Yes for the number of packages, if you enter the wall area and the coverage on the package. The depth is only a rough guide, because wall cavities have a fixed depth.