CFM Calculator

CFM, cubic feet per minute, is how much air a fan moves. Pick what you are sizing: a room by its air changes per hour, a bathroom exhaust fan, or a kitchen range hood. The calculator gives the airflow to look for on the fan label.

Enter your details

Room length.

Room width.

Ceiling height.

How many times an hour the room's air is replaced. 8 is the rate HVI gives for its bathroom rule; other rooms use other rates.

Airflow needed

128 CFM

960 cubic feet · 8 air changes per hour

Room airflow
Room volume12 × 10 × 8 ft = 960 cu ft
Air changes per hour8
Airflow128 CFM
Minutes per air change7.5

Formula: CFM = room volume (cu ft) × air changes per hour ÷ 60. To find the air changes a fan gives, reverse it: air changes per hour = CFM × 60 ÷ room volume.

Air changes per hour and CFM

An air change means moving a volume of air equal to the whole room. Air changes per hour (ACH) says how many times that happens in an hour. Because CFM is per minute, the hour has to be divided by 60.

Room volume (cu ft) = length × width × ceiling height
CFM = room volume × air changes per hour ÷ 60
Air changes per hour = CFM × 60 ÷ room volume

The reverse formula is useful when you already own a fan and want to know how often it replaces the air. The calculator starts at 8 air changes per hour, the figure the Home Ventilating Institute (HVI) gives for its bathroom rule of 1 CFM per square foot. Other rooms use other rates, so change it as needed.

Worked example: a 12 by 10 room

A room 12 ft long and 10 ft wide with an 8 ft ceiling holds 12 × 10 × 8 = 960 cubic feet of air. At 8 air changes per hour it needs 960 × 8 ÷ 60 = 128 CFM. Turned around, a 64 CFM fan in the same room gives 4 air changes per hour, one every 15 minutes.

Sizing a bathroom exhaust fan

HVI gives two rules for an intermittent bathroom fan, the kind you switch on when you use the room. For bathrooms up to 100 square feet its Bathroom Ventilation guide recommends 1 CFM per square foot of floor. Its guide How Much Ventilation Do I Need? adds a minimum of 50 CFM for an intermittent fan, which only matters for rooms under 50 square feet. Above 100 square feet it rates the room by its fixtures: 50 CFM for each toilet, shower and bathtub, and 100 CFM for a jetted tub.

  • A 5 by 8 ft bathroom has 40 sq ft. The area rule gives 40 CFM, the figure the Bathroom Ventilation guide uses for that room; the 50 CFM minimum for an intermittent fan raises it to 50 CFM, the rating the calculator shows
  • An 8 by 10 ft bathroom has 80 sq ft: 80 CFM
  • A 9 by 12 ft bathroom has 108 sq ft, over the limit, so with a toilet, a shower and a jetted tub it needs 50 + 50 + 100 = 200 CFM

HVI also says continuous ventilation at a minimum of 20 CFM may be used in place of an intermittent 50 CFM fan, and it advises a timer or control that keeps the fan running for at least 20 minutes after each use.

Sizing a kitchen range hood

For a hood against a wall, HVI recommends 100 CFM per linear foot of range, with a minimum of 40 CFM per foot. Over an island it recommends 150 CFM per linear foot, with a minimum of 50.

A standard 30 in range is 2.5 linear feet, so against a wall it calls for 2.5 × 100 = 250 CFM, with 100 CFM as the minimum. A 36 in range on an island calls for 450 CFM.

Range hood airflow by range width (HVI rates)
Range widthAgainst a wallOver an island
30 in250 CFM375 CFM
36 in300 CFM450 CFM
42 in350 CFM525 CFM
48 in400 CFM600 CFM

Getting the rated airflow in practice

A fan's CFM rating is measured under test conditions. Long duct runs, tight bends and small ducts all add resistance and cut the air a fan really moves, so choose a fan rated at the pressure your duct run will create, and follow the installation instructions. Building codes set their own ventilation minimums and some require make-up air for large hoods; your local building department has the final word.

To size the cooling for the same room, use the BTU calculator. To check when moist bathroom air will condense on a cold surface, try the dew point calculator.

CFM Calculator FAQ

How do I calculate CFM for a room?

Multiply length, width and ceiling height to get cubic feet, multiply by the air changes per hour you want, then divide by 60.

What size bathroom fan do I need?

Up to 100 sq ft, HVI recommends 1 CFM per square foot, and its ventilation guide sets 50 CFM as the minimum for an intermittent fan. An 8 by 10 ft bathroom needs 80 CFM.

How many CFM for a bathroom over 100 square feet?

Add up the fixtures: 50 CFM each for a toilet, shower and bathtub, and 100 CFM for a jetted tub, following the Home Ventilating Institute.

How many CFM does a 30 inch range hood need?

Against a wall, HVI recommends 100 CFM per linear foot, so 250 CFM for a 30 in range. Over an island the rate is 150 CFM per foot.

How many air changes per hour does a fan give?

Multiply the fan CFM by 60 and divide by the room volume in cubic feet. A 64 CFM fan in a 960 cu ft room gives 4 air changes per hour.

Guides