What size does an egress window have to be?
IRC Section R310 sets four numbers for an emergency escape and rescue opening:
- Net clear area: at least 5.7 square feet. Grade floor openings or below-grade openings need at least 5 square feet.
- Clear height: at least 24 inches.
- Clear width: at least 20 inches.
- Sill height: the bottom of the clear opening no more than 44 inches above the floor.
All four must pass. The two minimum sizes alone do not reach the area: 20 by 24 inches is only 3.33 square feet. With a 20 inch width, the clear height has to be 41.04 inches; with a 24 inch height, the width has to be 34.2 inches.
How is the net clear opening calculated?
Net clear opening (sq ft) = clear width (in.) × clear height (in.) ÷ 144
Height needed = 5.7 × 144 ÷ width (and at least 24 in.)
Width needed = 5.7 × 144 ÷ height (and at least 20 in.)
The City of Boise handout of the code says the net clear opening dimensions shall be obtained by the normal operation of the opening from the inside. Measure the open space itself, not the rough opening or the glass: only the part of the window that opens counts.
A 30 by 24 inch opening is 5 square feet. That meets the 5 square foot rule for a grade floor or below-grade opening, but not the 5.7 square feet asked elsewhere, so the same window fails on an upper floor.
| Clear width × height | Net clear area | Upper floor (5.7 sq ft) | Grade floor or below grade (5 sq ft) |
|---|---|---|---|
| 20 × 24 in. (both minimums) | 3.33 sq ft | Too small | Too small |
| 20 × 41.04 in. | 5.7 sq ft | Meets | Meets |
| 24 × 34.2 in. | 5.7 sq ft | Meets | Meets |
| 24 × 36 in. | 6 sq ft | Meets | Meets |
| 30 × 28 in. | 5.83 sq ft | Meets | Meets |
| 36 × 24 in. | 6 sq ft | Meets | Meets |
What are the rules for a basement window well?
When the opening sits below the ground outside, the code adds a window well (an area well): its horizontal area must be at least 9 square feet, with a horizontal projection and a width of at least 36 inches. A well deeper than 44 inches must have a permanently affixed ladder or steps.
A well that reaches out 36 inches from the wall and is 40 inches wide has 10 square feet, so it passes; at 48 inches deep it needs a ladder. Fill in the optional well fields of the egress window calculator to check yours.
Before you cut a new egress opening
- Ask your building department which code edition your town uses and whether a permit is needed. Local amendments can differ from the model code.
- Measure the clear opening of the window you plan to buy from its maker's data, with the window fully open as it opens in normal use.
- Keep the sill at 44 inches or less above the finished floor.
- For the stairs and ramps around the house, see the stair calculator and the wheelchair ramp calculator; for the wall around the window, the drywall calculator.
Sources
- International Code Council, code change document for IRC Section R310 (current text quoted: R310.2.1 net clear opening 5.7 square feet and 5 square feet for grade floor openings; R310.2.2 height 24 inches and width 20 inches; R310.2.3 sill not greater than 44 inches; R310.4.1 area well 9 square feet with projection and width of 36 inches; R310.4.2 ladder or steps for wells deeper than 44 inches).
- City of Boise, IRC Code Handout #438, Egress Windows, March 2022: the same figures, the exception for grade floor or below-grade openings (5 square feet) and the normal operation of the opening from the inside.
Planning check only: your local building department has the final word on emergency escape openings.
Egress Window Calculator FAQ
What is the minimum size of an egress window?
At least 5.7 square feet of net clear opening (5 square feet for grade floor or below-grade openings), at least 24 inches high and 20 inches wide, with the sill no more than 44 inches above the floor, under IRC Section R310.
Is a 20 by 24 inch window big enough for egress?
No. Both minimum sizes together give only 3.33 square feet, below 5.7. With a 20 inch width the clear height must reach 41.04 inches.
How do you measure the net clear opening of a window?
Open the window as it normally opens from the inside and measure the open space: clear width times clear height in inches, divided by 144, gives square feet.
How high can an egress window sill be?
The bottom of the clear opening can be no more than 44 inches above the floor, under IRC Section R310.
When does an egress window well need a ladder?
When the well is deeper than 44 inches, it needs a permanently affixed ladder or steps. The well itself needs at least 9 square feet, with a projection and a width of at least 36 inches.