Dew Point Calculator

Air holds water vapor, and when it touches something colder than its dew point, the vapor turns to droplets. Enter the air temperature and relative humidity to get the dew point, and add the temperature of a surface to see whether it will sweat.

Enter the air and the surface

From −40 to 50 °C (−40 to 122 °F). A minus sign is fine.

Above 0 and up to 100.

A window, a pipe, a cold glass or a wall, in the unit chosen above. Leave blank to skip the condensation check.

Dew point

60.2 °F

15.7 °C · becoming sticky, with muggy evenings

Dew point
Air temperature75 °F (23.9 °C)
Relative humidity60%
Dew point60.2 °F (15.7 °C)
Summer comfort at this dew pointBecoming sticky, with muggy evenings
Surface temperature55 °F (12.8 °C)
Surface versus the dew point5.2 °F (2.9 °C) below
CondensationExpected on this surface

Formula: with T in °C, γ = 17.625 × T ÷ (243.04 + T) + ln(RH ÷ 100) and dew point = 243.04 × γ ÷ (17.625 − γ). Water vapor condenses on a surface at or below the dew point of the air touching it. Below freezing, moisture can form as frost instead of dew. The comfort bands are the summer figures of the National Weather Service.

What is the dew point at 70 °F and 50% humidity?

At 70 °F air and 50% relative humidity the dew point is 50.5 °F (10.3 °C). Any surface at or below that temperature collects condensation. A window at 45 °F in that room is 5.5 °F below it and sweats, while a surface at 55 °F is 4.5 °F above it and stays dry.

By hand: 70 °F is 21.11 °C, so γ = 17.625 × 21.11 ÷ (243.04 + 21.11) + ln(0.50) = 0.7155, and the dew point is 243.04 × 0.7155 ÷ (17.625 − 0.7155) = 10.28 °C.

Dew point chart by air temperature and humidity

Read down for your air temperature and across for your humidity. At 80 °F and 70% the dew point is 69.3 °F, in the oppressive band.

Dew point (°F) by air temperature and relative humidity
Relative humidity60 °F air70 °F air80 °F air90 °F air
30%28374654
40%36455462
50%41516069
60%46556574
70%50606979
80%54647383
90%57677787

What the dew point is and how it feels

The National Weather Service describes the dew point as the temperature the air must be cooled to, at constant pressure, to reach 100% relative humidity. Comfort is given by dew point because it reflects how much water vapor is really there.

The National Weather Service (La Crosse office) gives summer bands: at or below 55 °F it is dry and comfortable, from 55 to 65 °F sticky, and at or above 65 °F oppressive. The bands do not describe winter air.

The Magnus formula the calculator uses

The calculator applies the Magnus approximation with the constants a = 17.625 and b = 243.04 °C that Alduchov and Eskridge recommended in 1996. Lawrence (2005, Bulletin of the American Meteorological Society) reports a relative error below 0.4% in saturation vapor pressure from −40 °C to 50 °C, the range the calculator accepts.

γ = a × T ÷ (b + T) + ln(RH ÷ 100)
Dew point = b × γ ÷ (a − γ)

T is in °C and RH in percent.

Worked example: 75 °F air at 60% humidity

The air is at 75 °F, which is 23.9 °C, with a relative humidity of 60%.

  • Dew point: 15.7 °C, which is 60.2 °F
  • A cold pipe or window at 55 °F is 5.2 °F below that dew point, so condensation is expected on it
  • A surface at 65 °F is above the dew point, so the check shows no condensation

At 30% humidity the dew point falls to 41.5 °F, and 80% pushes it up to 68.4 °F. At 100% humidity it equals the air temperature. Below 32 °F moisture forms as frost, not dew.

Checking a cold surface for condensation

Water vapor condenses on a surface at or below the dew point of the air touching it. The tool does not predict mold, and you must measure the real surface temperature.

Winter window: indoor air at 70 °F and 40% humidity has a dew point of 44.6 °F, so a pane at 40 °F is 4.6 °F below it and gets wet. At 30% humidity the dew point drops to 37.1 °F, and the pane is 2.9 °F above it, so it stays dry.

Summer pipe: air at 85 °F and 70% humidity has a dew point of 74.1 °F, so a cold water pipe at 62 °F, 12.1 °F below it, drips. The EPA advises insulating cold water pipes.

Dew point to ppm (moisture content)

Instrument makers state how dry a gas is as ppm by volume. Process Sensing Technologies gives the conversion as ppmV = (e ÷ P) × 1,000,000, where e is the water vapor pressure at the dew point and P is the total pressure, both in pascals. The Air Liquide table lists these values; this calculator does not output ppm.

Dew point and moisture in ppm (vol/vol), from the Air Liquide table
Dew pointWater vapor
−4 °F (−20 °C)1,020 ppm
−22 °F (−30 °C)378 ppm
−40 °F (−40 °C)128 ppm
−58 °F (−50 °C)39 ppm
−94 °F (−70 °C)2.54 ppm

Check one row: 128 ppm at one standard atmosphere (101,325 Pa) means e = 128 ÷ 1,000,000 × 101,325 = 12.97 Pa of water vapor. The table does not state its pressure, so for gas under pressure use the formula with the real P.

See also the BTU calculator, CFM calculator, insulation calculator, R-value chart and dew point guide.

Dew Point Calculator FAQ

What is the dew point at 70 °F and 50% humidity?

It is 50.5 °F, or 10.3 °C. A surface colder than that, such as a window at 45 °F, collects condensation.

At what dew point does the air feel muggy?

The National Weather Service says summer air at a dew point of 65 °F or more becomes oppressive, and between 55 and 65 °F it turns sticky.

Is dew point the same as humidity?

No. Relative humidity is a percent of the water vapor the air could hold at its temperature. The dew point is a temperature that reflects how much vapor is present.

Why do my windows fog up inside when it is cold out?

The glass is colder than the dew point of the indoor air. At 70 °F and 40% humidity the dew point is 44.6 °F, so a 40 °F pane is below it.

How do I convert a dew point to ppm?

Use ppmV = (e ÷ P) × 1,000,000, with e the water vapor pressure at the dew point and P the total pressure in pascals. Air Liquide lists a −40 °C dew point as 128 ppm (vol/vol).

Guides

Last updated . Free to use, no sign-up. How we check our numbers.