Running watts and starting watts
Champion Power Equipment, a generator maker, describes starting watts as typically 1 to 2 times the running wattage and lasting only a fraction of a second, although its own table shows larger ratios for some appliances. Cummins (2025) says that appliances with motors or compressors need much more power to start than to run, and that some motorized devices can need three, four or even five times their running power.
The sizing steps in both guides are alike. List the loads that will run together, add their running watts, then allow for the starting power of the one that needs the most.
Running watts = sum of (running watts × quantity)
Peak watts = running watts + largest single starting figure
Generator rating to look for = each total × (1 + headroom ÷ 100)
Which starting figure to enter
The makers do not use the same arithmetic. Champion's guide adds the starting wattage of the largest appliance to the total running watts. Cummins' guide adds the starting watts of the single largest motor load to the running watts of every other load, which leaves that load's own running watts out.
The calculator adds the number in the starting column to the total running watts, and it counts only the largest one, since the method assumes one appliance starts at a time. To follow Champion, enter the listed starting watts. To follow Cummins, enter the starting watts minus the running watts. If your manual lists no starting watts, leave the box at 0.
| Appliance | Running watts | Starting watts |
|---|---|---|
| Refrigerator | 150 to 400 | 800 to 1,200 |
| Sump pump (½ HP) | 800 to 1,050 | 1,300 to 2,150 |
| Furnace fan (½ HP) | 300 to 800 | 800 to 1,600 |
| Window AC (10,000 Btu) | 900 to 1,200 | 1,800 to 2,400 |
| Microwave | 600 to 1,200 | none needed |
| TV | 80 to 400 | none needed |
Champion's table is from its 2026 guide, What Size Generator Do I Need?. Its ranges are typical values and not a measurement of your own appliance, so use the label or the manual for each one. Champion says these appliances need no extra starting watts.
Worked example: four appliances
The list is a refrigerator at 400 running and 800 starting watts, a sump pump at 1,050 and 1,300, LED lights at 100, and a television at 200. The refrigerator, sump pump and television figures sit inside the Champion ranges, and the lights stand for about ten LED bulbs. They are examples, not measurements of any particular model.
- Running watts: 400 + 1,050 + 100 + 200 = 1,750 watts
- Largest starting figure: 1,300 watts, for the sump pump
- Peak watts: 1,750 + 1,300 = 3,050 watts
With 20 percent headroom typed in, the generator rating to look for rises to 2,100 running watts and 3,660 starting watts. Setting the refrigerator quantity to 2 raises the running load to 2,150 watts, and the peak stays tied to the largest single start: 3,450 watts. Without the sump pump, the other three loads total 700 running and 1,500 peak watts.
About headroom
The headroom box starts at 0, so the result is the bare total. Champion's guide says it is wise to choose a generator that exceeds the calculated wattage by a safe margin, and it gives no percentage. The Cummins guide gives none either, so the number is yours to choose. Your generator's manual or its maker can tell you how much of the rated output it should carry.
Connecting a generator safely
Champion says a portable generator must always be operated outside to avoid the dangers of carbon monoxide. For home backup it says the generator must be connected to a manual transfer switch installed by a licensed electrician. Follow the generator's manual, and for any connection to house wiring, use a licensed electrician who follows the National Electrical Code as adopted where you live.
To work out what the load costs on the grid, see the watts to amps calculator and the electricity cost calculator.
Generator Size Calculator FAQ
How do I calculate what size generator I need?
Add the running watts of everything that will run together, then add the largest starting figure. The example comes to 1,750 running and 3,050 peak watts.
What is the difference between running and starting watts?
Running watts keep an appliance going. Starting watts are the extra push that motors and compressors need for a moment at start-up.
Do I add the starting watts of every appliance?
No. Both guides add only the largest one, and the method assumes that appliances do not all start at the same instant.
How much headroom should I add?
The sources read do not give a percentage. Start from your generator's manual, or set a number you prefer in the headroom box.
Can I plug a portable generator into my house?
Champion says it must be connected to a manual transfer switch installed by a licensed electrician. Run it outdoors only.
Where do I find the watts of an appliance?
On the label or in the manual. The Champion table above lists typical ranges, but your own appliance may differ.