French Drain Calculator

A French drain 50 feet long, 12 inches wide and 18 inches deep needs 2.92 cubic yards of gravel, about 4.08 short tons with 5% extra, plus 50 feet of perforated pipe and 217 square feet of filter fabric. At a 1% slope the pipe falls 6 inches over that run. Enter your own trench below to see the same four figures for it.

Enter your trench

The run of pipe, from the high end to the outlet.

The width you dig.

From the surface to the bottom of the trench.

Enter 1 for 1 percent, or 0.125 with inches per foot. Sources differ on the minimum, so check your pipe maker and your local code.

Added to the fabric strip so the wrap closes over the top. The University of Washington standard asks for at least 4 in at overlapping edges. Check your fabric maker.

Use 0 for the exact figure. 5% is the same default as the gravel calculator.

The same planning figure as the gravel calculator, 1.4. Change it to match your supplier.

Gravel to order

2.917 cubic yards

≈ 78.75 cubic feet · about 4.08 short tons

Materials for the trench
Trench50 ft long, 12 in wide, 18 in deep
Gravel to fill it75 cu ft = 2.778 cu yd
Extra for settling and waste5%
Gravel to order2.917 cu yd (78.75 cu ft, 2.23 m³)
Gravel weight at 1.4 tons per cu yd4.08 short tons (3.70 t)
Perforated pipe50 ft (the length of the trench)
Fabric strip width52 in = trench width + 2 × depth + 4 in overlap
Filter fabric216.7 sq ft (24.1 sq yd)
Fall of the pipe
Slope1% (0.12 in per ft)
As a ratio1 in of fall for every 100 in of run
Total fall over the run6 in (6 in)
Fall along this run
Distance from the high endFall
12.5 ft1.5 in
25 ft3 in
37.5 ft4.5 in
50 ft6 in
The same run at other slopes
SlopeTotal fall
0.5%3 in
1%6 in
2%12 in
1/8 in per ft (1.04%)6.25 in
1/4 in per ft (2.08%)12.5 in

Gravel = length × width × depth, plus the extra, then cubic feet ÷ 27 for cubic yards and cubic yards × 1.4 for tons. The pipe takes up a little room, so the gravel figure is slightly on the high side. Fabric = (trench width + 2 × depth + overlap) × length, which wraps the whole trench with a strip. Fall = run × slope. The minimum slope varies by pipe maker, code and soil: check your pipe's installation guide and your local building department.

How much gravel does a French drain need?

Multiply the trench length by its width and its depth to get cubic feet, add a little extra for settling, then divide by 27 for cubic yards. Gravel is usually sold by weight, so multiply by the density. The calculator uses 1.4 short tons per cubic yard, the same planning figure as the gravel calculator.

Cubic feet = length × width × depth × (1 + extra)
Cubic yards = cubic feet ÷ 27
Tons = cubic yards × 1.4

For the trench above, 50 × 1 × 1.5 = 75 cubic feet, which is 2.778 cubic yards. With 5% extra the order is 2.917 cubic yards, about 4.08 tons.

Four trench sizes (5% extra gravel, 4 in fabric overlap)
TrenchGravel (cu yd)TonsFabric (sq ft)
25 ft by 12 in by 12 in0.971.3683
50 ft by 12 in by 18 in2.924.08217
50 ft by 18 in by 24 in5.838.17292
100 ft by 12 in by 18 in5.838.17433

How much perforated pipe and filter fabric do you need?

The pipe runs the full length of the trench, so 50 feet of trench takes 50 feet of pipe.

For the fabric, picture one strip that lines the bottom, climbs both sides and folds over the top. Its width is the trench width, plus twice the depth, plus an overlap. The Building America Solution Center, a U.S. Department of Energy program, describes landscape fabric under, around and over the washed gravel.

The default overlap is 4 inches, the least the University of Washington standard accepts where fabric edges overlap. The example strip is 12 + 2 × 18 + 4 = 52 inches wide, so the trench takes 216.7 square feet. ADS, a pipe maker, says that in sandy or silty soil either a geotextile wrap or gravel should keep soil out of the drainage line.

How much does a French drain pipe drop over its length?

The fall is the run times the slope. A 1% slope drops 1 inch for every 100 inches, so over 50 feet, which is 600 inches, the pipe drops 6 inches. A slope of 1/8 inch per foot is 1.04%, a drop of 6.25 inches over the same run.

Fall = run × slope
1% of 50 ft = 600 in × 0.01 = 6 in

The sources do not agree on one minimum, because they cover different jobs. ADS calls 0.2 inch per 10 feet generally adequate and says more fall drains faster. The University of Washington sets at least 0.5 percent for foundation drains. Oklahoma DEQ asks for 0.1 foot per 100 feet for a septic subsurface drain.

Fall of a 50 ft run at the slopes the sources mention
SlopeSourceFall
0.2 in per 10 ftADS1 in
0.1 ft per 100 ftOklahoma DEQ0.6 in
0.5%University of Washington3 in
1%Example only6 in
1/8 in per ft (1.04%)Example only6.25 in

This page does not recommend a slope. Follow your pipe maker's guide and your local building department.

How deep should the gravel be around the pipe?

The calculator fills the whole trench, so it assumes room above and below the pipe. The Building America Solution Center page describes at least 6 inches of washed gravel above the pipe and 2 inches below it, and ADS asks for at least 2 inches over the top.

What does this calculator leave out?

It does not know your soil, how much water the drain must carry, or where the pipe will empty. It gives quantities for planning and shopping, not a drainage design. Ask your local building department before you dig.

Sources

  • ADS, "Solving Home Drainage Problems": fall, bedding over the pipe, geotextile or gravel in sandy or silty soil.
  • University of Washington, Specifications Standards, section 33 46 00 Subdrainage (March 2017): 0.5 percent minimum slope, 4 inch fabric overlap.
  • Oklahoma Department of Environmental Quality, "Subsurface and Surface Drains" (October 2022): 0.1 foot per 100 feet.
  • Building America Solution Center (Pacific Northwest National Laboratory, U.S. Department of Energy), "Footing Drain Pipe": gravel above and below the pipe, fabric around the gravel.

French Drain Calculator FAQ

How many tons of gravel do I need for a 100-foot French drain?

For a trench 100 feet long, 12 inches wide and 18 inches deep, with 5% extra, order 5.83 cubic yards, about 8.17 short tons at 1.4 tons per cubic yard.

How much should a French drain pipe drop per foot?

Sources differ. ADS calls 0.2 inch per 10 feet generally adequate, and the University of Washington sets at least 0.5 percent for foundation drains. At 1/8 inch per foot a 50-foot run drops 6.25 inches. Follow your pipe maker and local code.

How wide should the filter fabric strip be for a French drain?

For a full wrap, add the trench width, twice the depth and an overlap. A trench 12 inches wide and 18 inches deep with a 4 inch overlap needs a strip 52 inches wide, which is 216.7 square feet for 50 feet of trench.

How do I turn cubic yards of French drain gravel into tons?

Multiply the cubic yards by the density. The calculator uses 1.4 short tons per cubic yard, the same planning figure as the gravel calculator, so 2.917 cubic yards is about 4.08 tons. Use your supplier's figure if it differs.

Do I need filter fabric around a French drain?

ADS says that in sandy or silty soil either a geotextile wrap or gravel should be used to keep soil out of the drainage line. Ask your pipe maker or local building department what your site needs.

Last updated . Free to use, no sign-up. How we check our numbers.