GuideHome & Renovation

Insulation R-Value Chart

Three charts in one place: R-value per inch of each insulation type, the R-value of common products at their thickness, and the levels ENERGY STAR recommends for your climate zone, plus the depth each target needs.

Updated 7 min read

Short answer

R-value measures how well insulation resists heat flow: the higher, the better. Typical R-value per inch:

  • Fiberglass batts: 2.5 to 4
  • EPS foam board: 3.8 to 4.4; XPS: 5
  • Polyiso board and closed-cell spray foam: about 6

ENERGY STAR says to add R-30 to R-60 to an uninsulated attic, depending on the climate zone.

Do the math for your project

Insulation Calculator

Bags or packages of batts or blown-in insulation for an area at your target R-value, with the depth.

Open the Insulation Calculator

What an R-value tells you

ENERGY STAR describes R-value as a measure of insulation's ability to resist heat traveling through it, and says the higher the R-value, the better the thermal performance. The U.S. Department of Energy uses the same idea in its Guide to Home Insulation: the ability of an insulation material to reduce heat flow is called its R-value.

An R-value belongs to a product at a given thickness. R-value per inch belongs to the material, and it lets you compare a batt with a foam board or a blown product. The Building America Solution Center, a DOE resource with content from the Pacific Northwest National Laboratory (PNNL), gives R-value per inch in ft²·h·°F/Btu per inch. Multiply R per inch by the thickness to estimate the R-value of a layer.

R-value of a layer = R-value per inch × thickness (in)
Thickness needed (in) = target R-value ÷ R-value per inch

R-value per inch chart

These are typical values, and a range means products differ. The last column comes from the same PNNL table and shows which materials it classes as air barriers.

R-value per inch of common insulation (Building America Solution Center)
InsulationR-value per inchAir barrier?
Fiberglass batt or board2.5 to 4No
Mineral wool rigid board3 to 4No
Expanded polystyrene (EPS) board3.8 to 4.4Yes
Extruded polystyrene (XPS) board5Yes
Polyisocyanurate (polyiso) boardAbout 6Yes
High-density polyurethane spray foamAbout 6Yes

PNNL lists fiberglass as low as 2.5 per inch and as high as 4, which is why two batts of the same thickness can carry different R-values. The label on the package is the number to trust for a specific product.

The same PNNL table also rates how much water vapor each material lets through (its vapor retarder class). It lists EPS as typically Class III (2.6 perm per inch), XPS and high-density spray foam as typically Class II (1.2 and 1 perm per inch), and polyiso as typically Class I, depending on its facing. Class I is 0.1 perm or less, Class II is above 0.1 and below 1.0 perm, and Class III is above 1.0 and below 10 perm. Batts and mineral wool board depend on their facing.

R-value of common products

The DOE Guide to Home Insulation (2010) lists R-values for products at the thickness they are sold or installed. It is the quickest way to see what a whole layer delivers.

R-value of common products at a given thickness (DOE Guide to Home Insulation)
ProductThicknessR-value
Fiberglass batts3.5 to 12 inR-13 to R-30
Loose fill (fiberglass, cellulose, mineral wool)8 to 23 inR-30 to R-50
Open-cell polyurethane spray foam3.5 inR-12.6
Closed-cell polyurethane spray foam1 inR-6.5
Expanded polystyrene foam board1 inR-3.8 to R-4.4
Extruded polystyrene foam board1 inR-5
Polyisocyanurate foam board1 inR-6.5

Note one difference between the two federal sources: DOE lists 1 inch of polyiso board at R-6.5, while the PNNL table says about 6 per inch. Both are typical figures, and the board's own label gives its rated value. Spray foam also varies: 3.5 inches of open-cell foam reaches R-12.6 in the DOE table, while 1 inch of closed-cell foam reaches R-6.5.

How thick the insulation must be

To turn a target R-value into inches, divide by the R-value per inch. The insulation calculator uses these estimating values for three common products: 2.5 per inch for loose fiberglass, 3.2 for fiberglass batts and 3.7 for cellulose.

Depth needed to reach a target R-value (estimating values used by the calculator)
TargetBlown fiberglassFiberglass battsBlown cellulose
R-135.2 in4.1 in3.5 in
R-197.6 in5.9 in5.1 in
R-3012 in9.4 in8.1 in
R-3815.2 in11.9 in10.3 in
R-4919.6 in15.3 in13.2 in
R-6024 in18.8 in16.2 in

Bag charts for blown insulation list a minimum thickness for each R-value, so read the chart on the bag you buy and blow to at least that depth. The table above is a planning estimate, not a replacement for the label.

Worked example: an attic in zone 5

An uninsulated attic floor measures 40 × 25 feet in climate zone 5. ENERGY STAR says to add R-60 to it. You plan to blow in cellulose, and the chart on the bag you picked lists 30 square feet per bag at R-60 (use the figure printed on your own bag).

  • Area: 40 × 25 = 1,000 square feet
  • Depth: 60 ÷ 3.7 = 16.2 inches of cellulose
  • Bags: 1,000 ÷ 30 = 33.33, so 34 bags
  • With 5 percent extra for obstacles: 1,050 ÷ 30, so 35 bags

The same attic in blown fiberglass would need about 24 inches to reach R-60. A better-insulated attic also lowers the cooling load of the rooms under it; the BTU calculator sizes a room air conditioner.

Open this example in the insulation calculator

Mistakes that waste money

  • Comparing per-inch values with product values. R-13 is a whole batt; 3.2 is per inch. Check which one a chart lists.
  • Trusting a typical value over the label. The ranges above are wide. Use the rated R-value and coverage printed on the product.
  • Expecting insulation to stop drafts. Fiberglass and mineral wool are not air barriers in the PNNL table, so air leaks need their own fix.
  • Using the attic column for walls or floors. ENERGY STAR gives separate figures for each, and they are lower for floors.
  • Skipping the code. A permit job must meet the local energy code, whatever a chart says.

To see what better insulation could save, compare your heating and cooling bills before and after with the electricity cost calculator, and see what a BTU is to read heating and cooling ratings.

Frequently asked questions

What R-value per inch does closed-cell spray foam have?

About 6 per inch for high-density spray foam in the PNNL table, and R-6.5 for 1 inch of closed-cell foam in the DOE Guide to Home Insulation.

What is the R-value of 1 inch of XPS foam board?

R-5. Both the PNNL table and the DOE Guide to Home Insulation list extruded polystyrene at 5 per inch. EPS is lower, at 3.8 to 4.4.

What R-value does ENERGY STAR recommend for floors?

R-13 in zones 1 and 2, R-19 in zones 3, 4A and 4B, R-30 in zones 4C, 5 and 6, and R-38 in zones 7 and 8.

How thick is R-60 blown cellulose?

About 16.2 inches, using the estimating value of 3.7 per inch that the calculator applies to cellulose. The bag chart gives the minimum thickness for the product you buy.

Do I need the same R-value in every climate zone?

No. ENERGY STAR says to add R-30 to an uninsulated attic in zone 1, R-49 in zones 2 and 3, and R-60 from zone 4 up.

Sources

  1. ENERGY STAR: Recommended Home Insulation R-Valuesenergystar.gov
  2. Building America Solution Center (US DOE, PNNL): Typical R-Values and Vapor Retarder Classifications for Common Insulation Materialsbasc.pnnl.gov
  3. US Department of Energy: Guide to Home Insulation (DOE/EE-0340, October 2010)energy.gov

Last updated . Free to read, no sign-up. How we check our numbers.