What an R-value tells you
ENERGY STAR describes R-value as a measure of insulation's ability to resist heat traveling through it, and says the higher the R-value, the better the thermal performance. The U.S. Department of Energy uses the same idea in its Guide to Home Insulation: the ability of an insulation material to reduce heat flow is called its R-value.
An R-value belongs to a product at a given thickness. R-value per inch belongs to the material, and it lets you compare a batt with a foam board or a blown product. The Building America Solution Center, a DOE resource with content from the Pacific Northwest National Laboratory (PNNL), gives R-value per inch in ft²·h·°F/Btu per inch. Multiply R per inch by the thickness to estimate the R-value of a layer.
R-value of a layer = R-value per inch × thickness (in)
Thickness needed (in) = target R-value ÷ R-value per inch
R-value per inch chart
These are typical values, and a range means products differ. The last column comes from the same PNNL table and shows which materials it classes as air barriers.
| Insulation | R-value per inch | Air barrier? |
|---|---|---|
| Fiberglass batt or board | 2.5 to 4 | No |
| Mineral wool rigid board | 3 to 4 | No |
| Expanded polystyrene (EPS) board | 3.8 to 4.4 | Yes |
| Extruded polystyrene (XPS) board | 5 | Yes |
| Polyisocyanurate (polyiso) board | About 6 | Yes |
| High-density polyurethane spray foam | About 6 | Yes |
PNNL lists fiberglass as low as 2.5 per inch and as high as 4, which is why two batts of the same thickness can carry different R-values. The label on the package is the number to trust for a specific product.
The same PNNL table also rates how much water vapor each material lets through (its vapor retarder class). It lists EPS as typically Class III (2.6 perm per inch), XPS and high-density spray foam as typically Class II (1.2 and 1 perm per inch), and polyiso as typically Class I, depending on its facing. Class I is 0.1 perm or less, Class II is above 0.1 and below 1.0 perm, and Class III is above 1.0 and below 10 perm. Batts and mineral wool board depend on their facing.
R-value of common products
The DOE Guide to Home Insulation (2010) lists R-values for products at the thickness they are sold or installed. It is the quickest way to see what a whole layer delivers.
| Product | Thickness | R-value |
|---|---|---|
| Fiberglass batts | 3.5 to 12 in | R-13 to R-30 |
| Loose fill (fiberglass, cellulose, mineral wool) | 8 to 23 in | R-30 to R-50 |
| Open-cell polyurethane spray foam | 3.5 in | R-12.6 |
| Closed-cell polyurethane spray foam | 1 in | R-6.5 |
| Expanded polystyrene foam board | 1 in | R-3.8 to R-4.4 |
| Extruded polystyrene foam board | 1 in | R-5 |
| Polyisocyanurate foam board | 1 in | R-6.5 |
Note one difference between the two federal sources: DOE lists 1 inch of polyiso board at R-6.5, while the PNNL table says about 6 per inch. Both are typical figures, and the board's own label gives its rated value. Spray foam also varies: 3.5 inches of open-cell foam reaches R-12.6 in the DOE table, while 1 inch of closed-cell foam reaches R-6.5.
Recommended R-values by climate zone
ENERGY STAR publishes the insulation levels it recommends when you add insulation to an existing home. Its guidance is based on the 2021 International Energy Conservation Code (IECC) residential provisions. Find your zone on the ENERGY STAR climate zone map, then read your row. ENERGY STAR heads the two attic columns "Add Insulation to Attic": the numbers are the R-value to add, not the total.
| Climate zone | Add to an uninsulated attic | Add to an attic with 3 to 4 in already | Floor |
|---|---|---|---|
| 1 | R-30 | R-25 | R-13 |
| 2 | R-49 | R-38 | R-13 |
| 3 | R-49 | R-38 | R-19 |
| 4A and 4B | R-60 | R-49 | R-19 |
| 4C, 5 and 6 | R-60 | R-49 | R-30 |
| 7 and 8 | R-60 | R-49 | R-38 |
For walls, ENERGY STAR gives advice for when the siding comes off. In an uninsulated wood-frame wall, blow insulation into the empty cavities, then add R-5 insulative sheathing under the new siding in zone 3, or R-5 to R-10 in zones 4 to 8. For an insulated 2×4 wall in zones 4 to 8 it recommends R-10 of insulative sheathing. For basement or crawlspace walls it lists R-5 sheathing or an R-13 batt in zone 3, R-10 sheathing or an R-13 batt in zones 4A and 4B, and R-15 sheathing or an R-19 batt in zones 4C and 5 to 8.
Code check: these are recommendations for existing homes. New construction and major remodels must meet the energy code your city or county has adopted, which may differ. Your building department has the last word.
How thick the insulation must be
To turn a target R-value into inches, divide by the R-value per inch. The insulation calculator uses these estimating values for three common products: 2.5 per inch for loose fiberglass, 3.2 for fiberglass batts and 3.7 for cellulose.
| Target | Blown fiberglass | Fiberglass batts | Blown cellulose |
|---|---|---|---|
| R-13 | 5.2 in | 4.1 in | 3.5 in |
| R-19 | 7.6 in | 5.9 in | 5.1 in |
| R-30 | 12 in | 9.4 in | 8.1 in |
| R-38 | 15.2 in | 11.9 in | 10.3 in |
| R-49 | 19.6 in | 15.3 in | 13.2 in |
| R-60 | 24 in | 18.8 in | 16.2 in |
Bag charts for blown insulation list a minimum thickness for each R-value, so read the chart on the bag you buy and blow to at least that depth. The table above is a planning estimate, not a replacement for the label.
Worked example: an attic in zone 5
An uninsulated attic floor measures 40 × 25 feet in climate zone 5. ENERGY STAR says to add R-60 to it. You plan to blow in cellulose, and the chart on the bag you picked lists 30 square feet per bag at R-60 (use the figure printed on your own bag).
- Area: 40 × 25 = 1,000 square feet
- Depth: 60 ÷ 3.7 = 16.2 inches of cellulose
- Bags: 1,000 ÷ 30 = 33.33, so 34 bags
- With 5 percent extra for obstacles: 1,050 ÷ 30, so 35 bags
The same attic in blown fiberglass would need about 24 inches to reach R-60. A better-insulated attic also lowers the cooling load of the rooms under it; the BTU calculator sizes a room air conditioner.
Mistakes that waste money
- Comparing per-inch values with product values. R-13 is a whole batt; 3.2 is per inch. Check which one a chart lists.
- Trusting a typical value over the label. The ranges above are wide. Use the rated R-value and coverage printed on the product.
- Expecting insulation to stop drafts. Fiberglass and mineral wool are not air barriers in the PNNL table, so air leaks need their own fix.
- Using the attic column for walls or floors. ENERGY STAR gives separate figures for each, and they are lower for floors.
- Skipping the code. A permit job must meet the local energy code, whatever a chart says.
To see what better insulation could save, compare your heating and cooling bills before and after with the electricity cost calculator, and see what a BTU is to read heating and cooling ratings.
Frequently asked questions
What R-value per inch does closed-cell spray foam have?
About 6 per inch for high-density spray foam in the PNNL table, and R-6.5 for 1 inch of closed-cell foam in the DOE Guide to Home Insulation.
What is the R-value of 1 inch of XPS foam board?
R-5. Both the PNNL table and the DOE Guide to Home Insulation list extruded polystyrene at 5 per inch. EPS is lower, at 3.8 to 4.4.
What R-value does ENERGY STAR recommend for floors?
R-13 in zones 1 and 2, R-19 in zones 3, 4A and 4B, R-30 in zones 4C, 5 and 6, and R-38 in zones 7 and 8.
How thick is R-60 blown cellulose?
About 16.2 inches, using the estimating value of 3.7 per inch that the calculator applies to cellulose. The bag chart gives the minimum thickness for the product you buy.
Do I need the same R-value in every climate zone?
No. ENERGY STAR says to add R-30 to an uninsulated attic in zone 1, R-49 in zones 2 and 3, and R-60 from zone 4 up.