What one BTU measures
The U.S. Energy Information Administration (EIA) defines a British thermal unit as the heat needed to raise the temperature of one pound of water by one degree Fahrenheit. It is a unit of energy, like the joule or the kilowatthour, and EIA uses it to compare the heat content of fuels that are sold in very different units.
One BTU is a small amount of energy. NIST gives the International Table BTU as 1,055.056 joules, so a single kilowatthour on your electric bill holds 3,412 BTU. That is why heating and cooling numbers run into the thousands, and why fuel totals are often quoted in millions of BTU.
1 BTU = 1,055.056 J
1 kWh = 3,412 BTU
1 therm = 100,000 BTU
BTU versus BTU per hour
A BTU is an amount of energy. A BTU per hour (BTU/h) is a rate: how much heat a machine moves or produces every hour. Air conditioner and heater labels are rates, even when the box just says "BTU". An 8,000 BTU air conditioner removes 8,000 BTU of heat from the room each hour it runs at full capacity.
The difference matters when you convert. Energy in BTU converts to kilowatthours, while a rate in BTU/h converts to watts. NIST lists one BTU per hour as 0.2931 watts, so one watt is about 3.412 BTU/h.
A 1,500-watt load is a handy check. Running for one hour, it uses 1.5 kWh, which is 1.5 × 3,412 = 5,118 BTU of energy. As a rate, 1,500 W is 1,500 ÷ 0.2931 = about 5,118 BTU/h. The two answers match because one is the other spread over one hour; the small gap comes from EIA rounding its factor to 3,412.
| From | Equals | Source of the factor |
|---|---|---|
| 1 BTU | 1,055.056 joules | NIST |
| 1 kilowatthour | 3,412 BTU | EIA |
| 1 therm | 100,000 BTU | EIA |
| 1 BTU per hour | 0.2931 watts | NIST |
| 1 watt | 3.412 BTU per hour | Worked out from NIST |
| 1 ton of cooling | 12,000 BTU per hour = 3,517 watts | NIST |
Tons of cooling and common AC ratings
Cooling equipment is also rated in tons. NIST defines a ton of refrigeration as 12,000 BTU per hour, which is 3,517 watts of cooling. A 24,000 BTU/h unit is a 2-ton unit, and a 6,000 BTU/h window unit is half a ton.
| Rating | Tons of cooling | Kilowatts of cooling |
|---|---|---|
| 5,000 BTU/h | 0.42 | 1.47 |
| 8,000 BTU/h | 0.67 | 2.34 |
| 12,000 BTU/h | 1 | 3.52 |
| 18,000 BTU/h | 1.5 | 5.28 |
| 24,000 BTU/h | 2 | 7.03 |
The kilowatts in the table are cooling output, not the electricity the unit draws. The electricity a unit draws is a separate figure, printed on its label in watts or amps. To turn that power draw into a monthly cost, use the electricity cost calculator.
How many BTU a room needs
ENERGY STAR publishes a sizing chart for room air conditioners. It matches the floor area of a room to a capacity in BTU per hour, assuming an 8-foot ceiling. A room of 150 up to 250 square feet calls for 6,000 BTU/h, 300 up to 350 square feet calls for 8,000, and 450 up to 550 square feet calls for 12,000.
The chart is then adjusted for the room itself. ENERGY STAR says to reduce capacity by 10 percent for a heavily shaded room, to increase it by 10 percent for a very sunny room, to add 600 BTU for each person beyond two who regularly use the room, and to add 4,000 BTU if the unit cools a kitchen. The BTU calculator applies the chart and all four adjustments for you.
Bigger is not better: ENERGY STAR warns that an oversized air conditioner costs more, wastes energy and cools the room before it removes the humidity, which leaves the air feeling damp and clammy.
Worked example: a sunny 14 ft by 22 ft bedroom
The bedroom measures 22 × 14 = 308 square feet. It gets full afternoon sun, and three people use it every evening.
- Chart value for 308 square feet (300 up to 350): 8,000 BTU/h
- Very sunny, plus 10 percent: 8,000 × 1.1 = 8,800 BTU/h
- One person beyond two: + 600 BTU/h
- Total: 9,400 BTU/h, which is 0.78 ton or 2.75 kW of cooling
Compare that figure with the capacity printed on the models you are looking at. If the same room were heavily shaded and used by two people, the chart value of 8,000 would drop by 10 percent instead. Better insulation also cuts the heat that comes in through the ceiling, which the insulation calculator helps you plan.
Comparing fuels by BTU
Every fuel holds a known amount of heat per unit sold. EIA publishes sample factors that let you put electricity, natural gas, propane, heating oil and firewood on the same scale. The last column shows how much of each you would buy to get one million BTU of heat content.
| Energy source | Unit | BTU per unit | Units for 1 million BTU |
|---|---|---|---|
| Electricity | 1 kilowatthour | 3,412 | 293.1 kilowatthours |
| Natural gas | 1 cubic foot | 1,036 | 965.3 cubic feet |
| Natural gas | 1 therm | 100,000 | 10 therms |
| Propane | 1 gallon | 91,452 | 10.9 gallons |
| Heating oil | 1 gallon | 138,500 | 7.2 gallons |
| Wood | 1 cord | 20,000,000 | 0.05 cords |
To compare prices, multiply the price of one unit by the number of units in one million BTU. For example, if propane costs P dollars a gallon, one million BTU of propane costs P × 10.93. Do the same with your electric rate and your gas price from the latest bills, and the cheapest heat content stands out.
This is heat content, not heat delivered. A furnace, boiler or stove turns only part of that heat into warm air or water, and the share depends on the appliance, so use the efficiency printed in its documentation when you compare two systems. For a propane tank, the propane calculator turns gallons into BTU and hours of run time. The EIA factor of 20 million BTU per cord of wood is a sample value: the real figure depends on the species and how dry the wood is.
Common mistakes with BTU numbers
- Mixing up BTU and BTU/h. A total in BTU converts to kWh or therms. A rating in BTU/h converts to watts or tons. Never divide one by the other without a time.
- Reading cooling kilowatts as power draw. A 12,000 BTU/h air conditioner moves about 3.52 kW of heat. The electricity it draws is a different number, printed on the nameplate.
- Using the room chart for a whole house. The ENERGY STAR chart is for one room and a room air conditioner. Central systems need a load calculation by a heating and cooling contractor.
- Treating heat content as heat delivered. A gallon of heating oil holds 138,500 BTU, but the heat you get depends on the efficiency of the burner.
- Rounding too early. Keep the full factor (3,412 BTU per kWh, 0.2931 W per BTU/h) until the last step, then round the answer.
For how much energy a typical home uses in a year, see how many kWh a house uses.
Frequently asked questions
How many joules are in one BTU?
NIST lists the International Table BTU as 1,055.056 joules, so about 1,055 J. One kilojoule is a little less than one BTU.
How many BTU are in one kilowatthour?
EIA uses 3,412 BTU per kilowatthour. So 10 kWh of electricity holds about 34,120 BTU of energy.
Is a BTU rating the same thing as BTU per hour?
On air conditioners and heaters, yes in practice: the number on the box is a rate in BTU per hour, even when the label shortens it to BTU. A BTU on its own is an amount of energy.
How many BTU does a therm of natural gas hold?
A therm is 100,000 BTU, according to EIA. EIA also gives 1,036 BTU for one cubic foot of natural gas.
How many BTU per hour is a 1-ton air conditioner?
One ton of cooling is 12,000 BTU per hour, which NIST gives as 3,517 watts. A 1.5-ton unit is 18,000 BTU/h.