Drywall thickness chart
Gypsum board, sold as drywall or under brand names like Sheetrock, comes in four common thicknesses. The weights below come from current USG data sheets: its regular panels in 1/4 and 3/8 inch, its lightweight UltraLight panel in 1/2 inch and its Firecode X panel in 5/8 inch. Panels with the same thickness from another maker or another product line weigh differently, so check the data sheet of the product you buy.
| Thickness | Metric | Weight (lb per sq ft), USG panel | 4 × 8 sheet (lb) | Typical use |
|---|---|---|---|---|
| 1/4 in. | 6.4 mm | 1.2 (regular) | 38.4 | Covering old walls and ceilings, base layer in multilayer walls |
| 3/8 in. | 9.5 mm | 1.4 (regular) | 44.8 | Repair and remodel work over existing surfaces |
| 1/2 in. | 12.7 mm | 1.25 (UltraLight) | 40 | Standard single layer for walls and ceilings in homes |
| 5/8 in. | 15.9 mm | 2.2 (Firecode X) | 70.4 | Fire-rated (Type X) assemblies, garage ceilings under rooms, ceilings at wide framing |
The uses in the last column come from the Canadian edition of the Gypsum Construction Handbook, distributed by USG and CGC. It describes 1/4 inch board as a utility panel for covering old wall and ceiling surfaces and for a base layer that improves sound control in multilayer walls. It describes 3/8 inch board as applied mainly in repair and remodel work over existing surfaces, and 1/2 inch as the panel recommended for single-layer construction in new building and remodeling. For curved walls, archways and staircases, USG sells a separate 1/4 inch flexible panel.
What the code says about thickness and framing
The 2021 International Residential Code (IRC), in its Table R702.3.5, sets the minimum gypsum board thickness for each framing spacing. The rows below are the ones for board fastened without adhesive.
| Thickness | Location | Board orientation to framing | Maximum framing spacing |
|---|---|---|---|
| 3/8 in. | Ceiling | Perpendicular | 16 in. on center |
| 3/8 in. | Wall | Either direction | 16 in. on center |
| 1/2 in. | Ceiling | Either direction | 16 in. on center |
| 1/2 in. | Ceiling | Perpendicular | 24 in. on center |
| 1/2 in. | Wall | Either direction | 24 in. on center |
| 5/8 in. | Ceiling | Either direction | 16 in. on center |
| 5/8 in. | Ceiling | Perpendicular | 24 in. on center |
| 5/8 in. | Wall | Either direction | 24 in. on center |
Two rules stand out. On walls, 1/2 inch board is allowed on studs up to 24 inches apart. On ceilings, both 1/2 and 5/8 inch board can span joists 24 inches apart only when the board runs perpendicular to the joists. At 16 inches, either direction is allowed.
A footnote of the same table adds limits for 3/8 inch board. It may not be used as a single layer on a ceiling that will get a water-based texture, or that must hold insulation above it. When a water-based texture is applied, the board must run perpendicular to the framing and the minimum goes from 3/8 to 1/2 inch on 16 inch framing and from 1/2 to 5/8 inch on 24 inch framing, unless 1/2 inch sag-resistant ceiling board is used.
Note: your city or county adopts a specific edition of the code and can amend it. The building department and the product label have the last word.
Garages and fire-rated drywall
The wall between a house and an attached garage has its own rule. Table R302.6 of the 2021 IRC asks for not less than 1/2 inch gypsum board or equivalent on the garage side, between the garage and the house and its attic. When there are habitable rooms above the garage, the ceiling must be not less than 5/8 inch Type X gypsum board or equivalent. The structure that supports that ceiling needs at least 1/2 inch board.
Type X is a fire-resistant core, not just a thicker panel. USG describes its UltraLight Firecode X as a 5/8 inch panel for applications where 5/8 inch Type X panels are required, and lists it under ASTM C1396, the standard for gypsum board. The IRC table also sets how a Type X garage ceiling below living space is hung: perpendicular to the ceiling framing, with fasteners at most 6 inches apart.
So a plain 5/8 inch panel and a 5/8 inch Type X panel are not interchangeable where a fire rating is required. Look for "Type X" or the maker's fire-rated brand name printed on the panel.
How much each thickness weighs
Thicker board is heavier, and that matters most on ceilings, where you hold the sheet overhead. Using the USG figures, a 12 × 12 ft ceiling of 144 square feet carries about 317 lb of 5/8 inch Firecode X board.
Lightweight panels narrow the gap. USG lists its 1/2 inch UltraLight panel at a nominal 1.25 lb per square foot, which is 180 lb for the same ceiling, and its 5/8 inch UltraLight Firecode X at 1.9 lb per square foot, or 274 lb.
For the count of sheets, the drywall calculator works the same for every thickness: the area is the same, only the weight and the price change.
Choosing the thickness room by room
- Walls on studs 16 or 24 in. apart: 1/2 inch is the usual choice, and the IRC allows it at both spacings. The stud calculator lays out the framing behind it.
- Ceilings on joists 16 in. apart: 1/2 inch, hung in either direction.
- Ceilings on trusses or joists 24 in. apart: 1/2 inch perpendicular to the framing, moving to 5/8 inch or 1/2 inch sag-resistant board if a water-based texture is planned.
- Ceilings under heavy insulation: never 3/8 inch. If you are adding attic insulation, the insulation calculator gives the amount, and the board below has to carry it.
- Garage: at least 1/2 inch on the house side walls, 5/8 inch Type X on a ceiling under bedrooms or other living space.
- Old plaster or worn walls: 1/4 or 3/8 inch fastened over the old surface, when the wall behind is sound and flat.
- Curved walls and arches: the 1/4 inch flexible panel, which USG sells for curved walls, archways and staircases.
Common mistakes
- Using 3/8 inch on a ceiling. It is limited to 16 inch framing, hung perpendicular, and it is ruled out under a water-based texture or insulation.
- Running 1/2 inch parallel to joists 24 inches apart. The IRC table allows 24 inch spacing on ceilings only with the board perpendicular to the framing.
- Buying plain 5/8 inch for a fire separation. Thickness alone is not a fire rating. The code calls for Type X where a rating is required.
- Mixing thicknesses on one wall. A patch of 3/8 inch next to 1/2 inch board leaves a step of 1/8 inch that the joint compound has to hide. Match the existing board when you repair.
- Forgetting the weight. A sheet of 5/8 inch Firecode X board at 2.2 lb per square foot is about 70 lb in a 4 × 8 size and about 106 lb in a 4 × 12, so plan help or a panel lift for ceilings.
Once the walls are hung and finished, the paint calculator uses the same wall area to estimate the paint.
Frequently asked questions
What is the standard thickness of drywall?
Half an inch (12.7 mm) is the usual thickness for walls and ceilings in homes. The Gypsum Construction Handbook calls 1/2 inch board the panel recommended for single-layer construction.
Is 5/8 drywall required on ceilings?
Not everywhere. The IRC allows 1/2 inch board on ceiling joists up to 24 inches apart when it runs perpendicular to them. It requires 5/8 inch Type X on a garage ceiling below living space, and 5/8 inch or sag-resistant 1/2 inch under a water-based texture on 24 inch framing.
Can I use 1/4 inch drywall over an old wall?
Yes, that is one of its main uses. The Gypsum Construction Handbook lists 1/4 inch board for covering old wall and ceiling surfaces. The old wall must be sound and flat, since thin board follows what is behind it.
What thickness of drywall goes between a garage and a house?
The IRC asks for at least 1/2 inch gypsum board on the garage side of the wall shared with the house. If there are living spaces above the garage, its ceiling must be at least 5/8 inch Type X.
How much heavier is 5/8 drywall than 1/2 drywall?
USG lists its lightweight 1/2 inch UltraLight panel at a nominal 1.25 lb per square foot and its 5/8 inch Firecode X panel at 2.2 lb, so a 4 × 8 sheet goes from about 40 lb to about 70 lb. Its 5/8 inch UltraLight Firecode X, at 1.9 lb, is about 61 lb.
Sources
- ICC: 2021 International Residential Code, Chapter 7 Wall Covering (Table R702.3.5)codes.iccsafe.org
- ICC: 2021 International Residential Code, Chapter 3 Building Planning (Table R302.6)codes.iccsafe.org
- USG: Sheetrock Gypsum Panels, Regular, submittal sheet WB1473usg.com
- USG: Sheetrock UltraLight Panels, submittal sheet WB2501usg.com
- USG: Sheetrock Firecode X Panels, submittal sheet WB2964usg.com
- USG: Sheetrock UltraLight Panels Firecode X, submittal sheet WB2598 (2019)usg.com
- USG: Sheetrock Brand Flexible Gypsum Panelsusg.com
- USG/CGC: Gypsum Construction Handbook (Canadian edition), chapter 1, drywall and veneer plaster productsusg.com