How many lumens per square foot does each room need?
Penn State's course page, citing the Illuminating Engineering Society (IES), lists 10 to 20 foot candles for living rooms and bedrooms, 30 to 40 for a kitchen, 20 to 50 for a bathroom and 30 for a garage. One foot candle is one lumen per square foot, so each number is lumens per square foot of floor.
The U.S. Department of Energy defines a footcandle as the illumination produced by one lumen spread over a 1 square foot area. That is why the foot candle levels in the IES table can be used directly as lumens per square foot. Lumens measure the light a bulb gives off. Foot candles measure the light that lands on a surface.
| Room or area | Lumens per sq ft | A 200 sq ft room needs |
|---|---|---|
| Living rooms, bedrooms and relaxation areas (ambient) | 10 to 20 | 2,000 to 4,000 lumens |
| Kitchen, general | 30 to 40 | 6,000 to 8,000 lumens |
| Kitchen, task areas (stove and sink) | 50 to 100 | 10,000 to 20,000 lumens |
| Bathrooms | 20 to 50 | 4,000 to 10,000 lumens |
| Home office and reading area | 20 to 50 | 4,000 to 10,000 lumens |
| Dining room | 30 to 40 | 6,000 to 8,000 lumens |
| Hallways and entryways | 5 to 20 | 1,000 to 4,000 lumens |
| Garage, general | 30 | 6,000 lumens |
| Garage, workbench | 100 | 20,000 lumens |
The last column is our own arithmetic: the lumens per square foot times 200. Hallways run from 5 to 20, a bathroom is wide at 20 to 50, and the kitchen has two lines because the stove and sink need more light than the rest of the room.
The Penn State table has no row for a workshop. The closest is the garage workbench at 100. The Department of Energy says that for detailed work, 200 foot candles or more allows more accuracy and less eyestrain, so a hobby bench with fine detail can need more than the table shows.
How do I calculate the lumens a room needs?
Multiply the floor area in square feet by the lumens per square foot for that kind of room. The result is the total lumens, added up over every bulb and fixture in the room. A bulb's package gives its lumens, so you divide the total by that number to count bulbs.
Floor area (sq ft) = length (ft) × width (ft)
Total lumens = floor area × lumens per sq ft
Bulbs = total lumens ÷ lumens per bulb, rounded up
Take a kitchen 15 feet long and 12 feet wide. The floor area is 15 × 12 = 180 square feet. At the general kitchen level of 30 to 40, the room needs 180 × 30 = 5,400 to 180 × 40 = 7,200 lumens in all.
The counters need more. Say 12 feet of counter 2 feet deep, which is 24 square feet. At the task level of 50 to 100, that surface needs 1,200 to 2,400 lumens to land on it. Lights over the counter have to carry more than the room average.
If you do not know the floor area, the square footage calculator finds it for a rectangle or an odd shape.
How many lumens does a 100 to 400 square foot room need?
A 100 square foot bedroom needs 1,000 to 2,000 lumens, and a 400 square foot kitchen needs 12,000 to 16,000 for general light. The table multiplies five common room sizes by the IES levels, so find the nearest size and read across.
| Room size | Bedroom or living room | Kitchen, general | Bathroom | Garage, general |
|---|---|---|---|---|
| 100 sq ft | 1,000 to 2,000 | 3,000 to 4,000 | 2,000 to 5,000 | 3,000 |
| 150 sq ft | 1,500 to 3,000 | 4,500 to 6,000 | 3,000 to 7,500 | 4,500 |
| 200 sq ft | 2,000 to 4,000 | 6,000 to 8,000 | 4,000 to 10,000 | 6,000 |
| 300 sq ft | 3,000 to 6,000 | 9,000 to 12,000 | 6,000 to 15,000 | 9,000 |
| 400 sq ft | 4,000 to 8,000 | 12,000 to 16,000 | 8,000 to 20,000 | 12,000 |
Method: each cell is the room size times the low and high lumens per square foot of the row above. The bathroom range is wide because the source gives 20 to 50. Pick the low end for a room used for relaxing, and a higher value where you read, groom or work.
A garage at 30 lumens per square foot needs 12,000 lumens at 400 square feet. The workbench is a separate spot. At 100, a bench of 32 square feet, 4 feet by 8 feet, needs 3,200 lumens landing on it. Applying 100 to a whole 400 square foot garage would call for 40,000 lumens, which is not what the table means.
How many bulbs or recessed lights does that make?
Divide the total lumens by the lumens on each bulb's package and round up. With bulbs of 800 lumens, the brightness ENERGY STAR gives as the minimum for a bulb replacing an old 60 watt incandescent, a 200 square foot bedroom needs 3 to 5 bulbs. The table counts 800 lumen bulbs for each room size.
| Room size | Bedroom or living room | Kitchen, general | Bathroom |
|---|---|---|---|
| 100 sq ft | 2 to 3 | 4 to 5 | 3 to 7 |
| 150 sq ft | 2 to 4 | 6 to 8 | 4 to 10 |
| 200 sq ft | 3 to 5 | 8 to 10 | 5 to 13 |
| 300 sq ft | 4 to 8 | 12 to 15 | 8 to 19 |
| 400 sq ft | 5 to 10 | 15 to 20 | 10 to 25 |
Bulbs are one way to count. With recessed lights, the layout often fixes the number first. Our recessed lighting calculator spaces lights at half the ceiling height, so the 15 by 12 foot kitchen with an 8 foot ceiling gets 12 lights in a 4 by 3 grid.
Check that layout against the lumens. If each of the 12 lights gives 800 lumens, the room receives 9,600 lumens, or 53.3 per square foot. The calculator reports that 7 lights reach the target of 30 and 9 reach 40. The layout gives more than the room needs, so a dimmer or a lower output light fits better.
The lumens per light that suit this layout come from dividing: 5,400 ÷ 12 = 450 lumens each for 30, and 7,200 ÷ 12 = 600 for 40. With 600 lumen lights and a target of 40, the calculator confirms that the target is reached, using 12 lights. With 450 lumens and a target of 30, it is reached.
Why might my room need more or less light than the chart?
The chart is a floor-area average, and real rooms differ in what they are used for. The Department of Energy gives levels by activity: 30 to 50 foot candles for most home and office work, 200 or more for detailed work, and 5 to 20 simply to find your way around at night.
These reasons can move your number inside the range, or beyond it:
- What you do there. A bedroom used for reading belongs nearer the 20 end, and a bedroom used only for sleeping can sit at 10.
- Where the light lands. A foot candle counts light on a surface. The chart divides by floor area, so it cannot tell how much reaches a counter, a desk or a page.
- Control. Dimmers let one fixture serve both the low and the high end of a range, so a room can be set up for the high end and turned down.
- Layers. General light from the ceiling and task light at the counter or desk split the job, as the two kitchen rows of the table show.
The sources do not publish a correction for wall color, ceiling height or fixture type, so none is applied here. Treat the totals as a planning estimate and adjust after you live with the room.
A living room with a television is still a living room in the table. Choose the screen size and the viewing distance with the TV size calculator, then use dimmable lights so the room can drop to the low end while you watch.
How do lumens, watts and running cost fit together?
Lumens measure brightness and watts measure the power a bulb draws. ENERGY STAR says brightness is measured in lumens, not watts, and to find the bulbs with the lumens you need and choose the one with the lowest wattage. The table shows its minimum lumens for old incandescent sizes.
| Old incandescent bulb | Minimum lumens | Bulbs for 3,000 lumens |
|---|---|---|
| 40 watts | 450 | 7 |
| 60 watts | 800 | 4 |
| 75 watts | 1,100 | 3 |
| 100 watts | 1,600 | 2 |
| 150 watts | 2,600 | 2 |
Reading it for a 100 square foot kitchen that needs 3,000 lumens at 30 per square foot: four bulbs of 800 lumens reach it, and so do two of 1,600. The bulb counts are our arithmetic, rounded up.
Running cost follows the watts on the label, not the lumens. Energy in kilowatt-hours is watts × hours ÷ 1,000. The electricity cost calculator multiplies it by your rate. Its default case, one 100 watt bulb for 5 hours a day over 30 days, is 100 × 5 × 30 ÷ 1,000 = 15 kWh, at the rate set in the calculator. The Department of Energy says a 100 watt incandescent lamp emits about 1,600 lumens, so if the default bulb is incandescent, it gives about 1,600 lumens. For the unit itself, see what a kilowatt-hour is.
A bulb with the same lumens and fewer watts costs less to run. Compare the lumens and the watts on the label, and read your own bill for the rate.
What mistakes make a room too dark or too bright?
The common mistakes are buying by watts, applying a task level to a whole floor, rounding the bulb count down and sizing a layout without checking its lumens. Each mistake is easy to catch with the arithmetic above before you shop, and the list below shows the numbers for each.
- Buying by watts. A package that only says 60 watts tells you the power draw. Look for the lumens line on the label.
- Using the workbench level on the whole garage. 100 lumens per square foot on 400 square feet is 40,000 lumens. The bench alone needs 3,200.
- Rounding down. 5,400 lumens from 800 lumen bulbs is 6.75 bulbs, so buy 7.
- Ignoring the rest of the room. A hallway is 5 to 20, so lighting it like the kitchen wastes power.
- Counting lights from the layout only. In the 15 by 12 foot kitchen the grid gave 12 lights, more than the 7 that reach 30 at 800 lumens each. Count both in the recessed lighting calculator, then choose the output per light.
Last, work in whole rooms. Add up the lumens of every fixture in the room, including lamps, and compare the total with the table before you add more.
Check locally: these levels are recommendations, not code. For new wiring, circuits or recessed fixtures in an insulated ceiling, follow the fixture instructions and the local electrical code, and ask a licensed electrician.
Frequently asked questions
How many lumens do I need for a bedroom?
The IES level published by Penn State is 10 to 20 lumens per square foot for bedrooms and living rooms. A 12 by 12 foot bedroom is 144 square feet, so it needs 1,440 to 2,880 lumens.
How many lumens per square foot is right for a kitchen?
The IES levels are 30 to 40 lumens per square foot for general kitchen light, and 50 to 100 for the task areas around the stove and sink.
Is a foot candle the same as a lumen per square foot?
Yes. The Department of Energy defines a footcandle as the illumination from one lumen spread over one square foot, so 30 foot candles is 30 lumens per square foot.
How many lumens is a 60 watt bulb?
ENERGY STAR lists 800 minimum lumens for a bulb that replaces an old 60 watt incandescent. Read the lumens on the package, because brightness is measured in lumens and not in watts.